SØG - mellem flere end 8 millioner bøger:

Søg på: Titel, forfatter, forlag - gerne i kombination.
Eller blot på isbn, hvis du kender dette.

Viser: Open Microfluidics

Open Microfluidics, 1. udgave
Søgbar e-bog

Open Microfluidics Vital Source e-bog

Jean Berthier, Kenneth A. Brakke og Erwin Berthier
(2016)
John Wiley & Sons
2.419,00 kr.
Leveres umiddelbart efter køb
Open Microfluidics

Open Microfluidics

Jean Berthier, Kenneth A. Brakke og Erwin Berthier
(2016)
Sprog: Engelsk
John Wiley & Sons, Limited
2.487,00 kr.
ikke på lager, Bestil nu og få den leveret
om ca. 10 hverdage

Detaljer om varen

  • 1. Udgave
  • Vital Source searchable e-book (Reflowable pages)
  • Udgiver: John Wiley & Sons (Juli 2016)
  • Forfattere: Jean Berthier, Kenneth A. Brakke og Erwin Berthier
  • ISBN: 9781118720820
Open microfluidics or open-surface is becoming fundamental in scientific domains such as biotechnology, biology and space. First, such systems and devices based on open microfluidics make use of capillary forces to move fluids, without any need for external energy. Second, the “openness” of the flow facilitates the accessibility to the liquid in biotechnology and biology, and reduces the weight in space applications. This book has been conceived to give the reader the fundamental basis of open microfluidics. It covers successively The theory of spontaneous capillary flow, with the general conditions for spontaneous capillary flow, and the dynamic aspects of such flows. The formation of capillary filaments which are associated to small contact angles and sharp grooves. The study of capillary flow in open rectangular, pseudo-rectangular and trapezoidal open microchannels. The dynamics of open capillary flows in grooves with a focus on capillary resistors. The case of very viscous liquids is analyzed. An analysis of suspended capillary flows: such flows move in suspended channels devoid of top cover and bottom plate. Their accessibility is reinforced, and such systems are becoming fundamental in biology. An analysis of “rails” microfluidics, which are flows that move in channels devoid of side walls. This geometry has the advantage to be compatible with capillary networks, which are now of great interest in biotechnology, for molecular detection for example. Paper-based microfluidics where liquids wick flat paper matrix. Applications concern bioassays such as point of care devices (POC). Thread-based microfluidics is a new domain of investigation. It is seeing presently many new developments in the domain of separation and filtration, and opens the way to smart bandages and tissue engineering.   The book is intended to cover the theoretical aspects of open microfluidics, experimental approaches, and examples of application.
Licens varighed:
Bookshelf online: 5 år fra købsdato.
Bookshelf appen: ubegrænset dage fra købsdato.

Udgiveren oplyser at følgende begrænsninger er gældende for dette produkt:
Print: 10 sider kan printes ad gangen
Copy: højest 2 sider i alt kan kopieres (copy/paste)

Detaljer om varen

  • Hardback: 336 sider
  • Udgiver: John Wiley & Sons, Limited (Oktober 2016)
  • Forfattere: Jean Berthier, Kenneth A. Brakke og Erwin Berthier
  • ISBN: 9781118720806

Open microfluidics or open-surface is becoming fundamental in scientific domains such as biotechnology, biology and space. First, such systems and devices based on open microfluidics make use of capillary forces to move fluids, without any need for external energy. Second, the "openness" of the flow facilitates the accessibility to the liquid in biotechnology and biology, and reduces the weight in space applications.

This book has been conceived to give the reader the fundamental basis of open microfluidics. It covers successively

  • The theory of spontaneous capillary flow, with the general conditions for spontaneous capillary flow, and the dynamic aspects of such flows.
  • The formation of capillary filaments which are associated to small contact angles and sharp grooves.
  • The study of capillary flow in open rectangular, pseudo-rectangular and trapezoidal open microchannels.
  • The dynamics of open capillary flows in grooves with a focus on capillary resistors. The case of very viscous liquids is analyzed.
  • An analysis of suspended capillary flows: such flows move in suspended channels devoid of top cover and bottom plate. Their accessibility is reinforced, and such systems are becoming fundamental in biology.
  • An analysis of "rails" microfluidics, which are flows that move in channels devoid of side walls. This geometry has the advantage to be compatible with capillary networks, which are now of great interest in biotechnology, for molecular detection for example.
  • Paper-based microfluidics where liquids wick flat paper matrix. Applications concern bioassays such as point of care devices (POC).
  • Thread-based microfluidics is a new domain of investigation. It is seeing presently many new developments in the domain of separation and filtration, and opens the way to smart bandages and tissue engineering.

The book is intended to cover the theoretical aspects of open microfluidics, experimental approaches, and examples of application.
Acknowledgements xi Preface xiii Online Materials xv Introduction 1 1 Theory of Spontaneous Capillary Flows 13
1.1 Introduction 13
1.2 Quasi-static Approach to SCF 16
1.2.1 Open and Confined Systems 17
1.2.2 Theoretical Approach 17
1.2.3 Numerical Approach 21
1.2.3.1 Numerical Verification of the Capillary Force 22
1.2.3.2 Composite Confined Channel 22
1.2.3.3 Composite Open Channel 23
1.2.3.4 Fiber Bundle 24
1.2.3.5 Usual Geometries 27
1.2.3.6 Conclusion 27
1.2.4 Dynamic Aspects 27
1.2.4.1 Generalization of the Lucas-Washburn-Rideal Law to Composite, Confined Microchannels of Arbitrary Cross-section 30
1.2.4.2 Theory 30
1.2.4.3 Magnitude of Capillary Velocities 36
1.2.4.4 Experimental Results for Confined Channels 38
1.2.4.5 Conclusion 39
1.3 The Dynamics of Spontaneous Capillary Flows in Open-surface Channels 40
1.3.1 The Dynamics of SCF 40
1.3.2 Confined Rectangular Channels 42
1.3.3 Open Rectangular U-grooves 44
1.3.4 Suspended Rectangular Channels 45
1.3.5 Experiments 46
1.3.6 Comparison 46
1.4 Dynamic Contact Angle 49
1.5 Conclusion 53
1.6 References 53 2 Capillary Filaments 57
2.1 Introduction 57
2.2 Concus-Finn Theory 57
2.2.1 Numerical Approach 60
2.2.2 Example of Capillary Filaments in a Micro-beaker 60
2.2.3 Example of a Capillary Filament in a Micro Petri Dish 60
2.2.4 Extended Concus-Finn Relation 62
2.2.5 Capillary Filaments in a Non-ideal Corner 63
2.3 Capillary Filaments in Rectangular U-grooves 65
2.3.1 Capillary Flow Regimes with No Capillary Filaments (> 45°) 66
2.3.2 Capillary Flow Regimes with Capillary Filaments ( 45° 103
3.5.2 Concus-Finn Filaments in Sharp Curves, > 45° 103
3.6 Extrapolation to the Coiling of the Flow Around a Curved Corner 104
3.7 Converging U-channels 105
3.8 Diverging U-channels 105
3.8.1 No CF Filaments 106
3.8.2 CF Filaments 108
3.9 U-groove with a Sudden Enlargement 108
3.9.1 Smooth Enlargement 109
3.9.2 Enlargement with Sharp Edges 110
3.9.3 U-groove Exiting into a Cylinder 112
3.9.4 U-groove Crossing a Polygonal Cavity 113
3.10 Open Capillary Valves 114
3.10.1 Capillary Stop Valves 114
3.10.2 Trigger Valves 115
3.11 Bifurcation 116
3.12 Capillary Filtration 118
3.13 Capillary Flow Mixing 119
3.14 Generalization: Substrate Patterned with Parallel Rectangular U-grooves 119
3.14.1 Substrate Patterned with U-grooves 119
3.14.2 Open, Rectangular U-groove with Sub-grooves in the Bottom Plate 120
3.14.3 Applications 121
3.15 Conclusion 121
3.16 References 122 4 Dynamics of Capillary Flow in a Channel with Constrictions and Enlargements 125
4.1 Introduction 125
4.2 Channel Constriction and Enlargement 126
4.2.1 Theory 126
4.2.2 Numerical Results and Discussion 130
4.2.2.1 Straight Channel 131
4.2.2.2 Channel with a Constricted Section 131
4.2.2.3 Channel with an Enlarged Section 132
4.2.3 Experimental Results 134
4.2.3.1 Constriction 135
4.2.3.2 Enlargement 136
4.2.4 Conclusion 137
4.3 SCF in a U-groove with Multiple Change of Cross-section 137
4.3.1 Theoretical Approach 138
4.3.2 Experimental Approach 140
4.3.2.1 Winding Open Rectangular U-groove 140
4.3.2.2 Open Rectangular U-groove with Constricted Sections 141
4.3.2.3 Open Rectangular U-groove with Cylindrical Chambers 144
4.3.3 Comparison with the Numerical Approach 145
4.4 Conclusion 146
4.5 References 149 Appendix
4.1 Velocity Model for Open Rectangular Channels 150 Appendix
4.2 Velocity Model for Cylindrical Tubes 152 Appendix
4.3 Friction in a Rectangular Open Channel 155 5 Suspended Capillary Flows 157
5.1 Introduction 157
5.2 Theory 158
5.3 Quasi-static Numerical Approach 159
5.3.1 Effect of Gravity 162
5.4 Dynamic Approach 162
5.4.1 Closed-form Expression of the Velocity for Newtonian Fluids 162
5.4.2 Channel Characteristics Corresponding to Maximum Velocities 164
5.4.3 Examples from Experiments 166
5.4.3.1 Suspended Channel Fabrication 167
5.4.3.2 Preparation of the Solutions and Liquid Characterization 168
5.4.3.3 Tinted Water 168
5.4.3.4 IPA Solutions 169
5.4.3.5 Whole Blood 169
5.4.3.6 Alginate Solutions 171
5.5 Comparison of a U-channel and a Suspended Channel 174
5.6 Suspended Microfluidics in Channels of Varying Section 175
5.6.1 Diverging Straight Walls 175
5.6.2 Sudden Enlargement of Suspended Channels 179
5.6.2.1 Quasi-static Approach 179
5.6.2.2 Dynamic Approach 183
5.6.3 Converging Suspended Channels 183
5.6.4 X-shape Suspended Channels 184
5.7 Capillary Flow in a Suspended Tapering Channel 186
5.8 Suspended Microfluidics in Suspended V-shaped Channels 188
5.9 Capillary Flow Over a Hole 189
5.10 Introduction to Two-phase Suspended Microflows 191
5.10.1 Parallel Walls 194
5.10.2 Tapered Walls 197
5.10.2.1 Converging Channel 197
5.10.2.2 Diverging Channel 198
5.10.3 Examples and Applications of Suspended Microfluidics 199
5.10.3.1 Formation of μDots 199
5.10.3.2 Towards a Giant Polymeric Micromembrane 201
5.10.3.3 Suspended Microfluidics for Measurement of Contact Angles 201
5.11 Conclusion 203
5.12 References 203 6 Spontaneous Capillary Flow Between Horizontal Rails 207
6.1 Introduction 207
6.2 Spontaneous Capillary Flows Between Rails 209
6.3 Winding Channels 210
6.4 Diverging Rails 211
6.5 Rails with Lateral Enlargement 212
6.6 Converging Rails 212
6.7 Rails with Constriction 212
6.8 Stopping a Capillary Flow at a Neck 213
6.9 SCF in Sinusoidal Railed Channels 215
6.10 Divisions and Bifurcations 217
6.10.1 Flow Separation 217
6.10.2 Flow Around a Hole 217
6.10.2.1 Two Plates Pierced by a Hole 218
6.10.2.2 Bottom Plate Pierced by a Hole 221
6.10.2.3 Rails Around a Hole 221
6.10.3 Capillary Flow Around Pillars 224
6.10.3.1 Single Pillar 224
6.10.3.2 Multiple Pillars 225
6.11 Conclusion 227
6.12 References 227 7 Paper-based Microfluidics 229
7.1 Introduction 229
7.2 Principles of Labs-on-Paper and Paper-based Devices 230
7.3 Paper-based Microfluidics 231
7.3.1 Spontaneous Imbibition-wicking 231
7.3.2 Fully Wetted Medium - Darcy''s law 234
7.3.3 Velocity in Paper Strips of Piecewise Varying Width 236
7.3.4 Filtration and Separation 237
7.3.5 Mixing 238
7.3.6 Y-junctions 240
7.3.7 Hydrodynamic Focusing 241
7.3.8 H-filters: Separation and Extraction 242
7.3.9 Valves 243
7.3.10 Architecture for Time Sequencing 244
7.3.11 3D paths - Fluidic Origamis 244
7.3.12 Electrokinetics on Paper 244
7.4 Paper-based Systems Fabrication and Detection 245
7.4.1 Fabrication Techniques of Paper Strips 246
7.4.2 Fabrication Techniques of μPADs 247
7.4.2.1 Hydrophobic Barrier 247
7.4.2.2 Hydrophobization of the Substrate 247
7.4.3 Functionalization and Loading of Reagents 249
7.4.4 Detection 249
7.4.4.1 Colorimetry 249
7.4.4.2 Electrochemistry(EC) 250
7.4.4.3 Chemiluminescence 251 8 Fiber-based Microfluidics 257
8.1 Introduction 257
8.2 Droplet on Fibers 259
8.2.1 Droplet on a Horizontal Fiber 259
8.2.2 Small Droplet 260
8.2.2.1 Effect of Gravity on Small Droplets 261
8.2.2.2 Large Droplet 261
8.2.3 Droplet Between Fibers 263
8.2.3.1 Droplet Between Two Parallel Fibers 263
8.2.3.2 Non-parallel Fibers in the Same Plane 264
8.2.3.3 Drop Between Two Fibers - General Case 265
8.2.3.4 Droplet Sliding Down a Fiber 266
8.3 SCF Guided by Fibers 268
8.3.1 Approximate General Condition for Spontaneous Capillary Flow in a Fiber Bundle 268
8.3.2 Geometrical
De oplyste priser er inkl. moms

Senest sete

Polyteknisk Boghandel

har gennem mere end 50 år været studieboghandlen på DTU og en af Danmarks førende specialister i faglitteratur.

 

Vi lagerfører et bredt udvalg af bøger, ikke bare inden for videnskab og teknik, men også f.eks. ledelse, IT og meget andet.

Læs mere her


Trykt eller digital bog?

Ud over trykte bøger tilbyder vi tre forskellige typer af digitale bøger:

 

Vital Source Bookshelf: En velfungerende ebogsplatform, hvor bogen downloades til din computer og/eller mobile enhed.

 

Du skal bruge den gratis Bookshelf software til at læse læse bøgerne - der er indbygget gode værktøjer til f.eks. søgning, overstregning, notetagning mv. I langt de fleste tilfælde vil du samtidig have en sideløbende 1825 dages online adgang. Læs mere om Vital Source bøger

 

Levering: I forbindelse med købet opretter du et login. Når du har installeret Bookshelf softwaren, logger du blot ind og din bog downloades automatisk.

 

 

Adobe ebog: Dette er Adobe DRM ebøger som downloades til din lokale computer eller mobil enhed.

 

For at læse bøgerne kræves særlig software, som understøtter denne type. Softwaren er gratis, men du bør sikre at du har rettigheder til installere software på den maskine du påtænker at anvende den på. Læs mere om Adobe DRM bøger

 

Levering: Et download link sendes pr email umiddelbart efter købet.

 


Ibog: Dette er en online bog som kan læses på udgiverens website. 

Der kræves ikke særlig software, bogen læses i en almindelig browser.

 

Levering: Vores medarbejder sender dig en adgangsnøgle pr email.

 

Vi gør opmærksom på at der ikke er retur/fortrydelsesret på digitale varer.