This second part is an independent and comprehensive guide for electrical engineers, responsible for the project planning of cable installations. It includes numerous graphic charts and comprehensive tables, presenting project planning data, constructional specifications, ratings, electrical data of cables, insulated wires, flexible cables, and accessories.
IntroductionInsulated Wires and Flexible Cables1 Selection of Cables1.
1 Summary and Application1.
1.
1 Building Wires and Cables1.
1.
2 Single-Core Cables for Internal Wiring, General and Special Purposes1.
1.
3 Heat-Resistant Cables and Cords1.
1.
4 Cables for Measuring, Controlling and Regulating (MSR)1.
1.
5 Flexible PVC-Sheathed Cords1.
1.
6 Flexible Rubber-Sheathed Cords and Cables1.
1.
7 Welding Cables1.
1.
8 Flexible Cables for Forced Guiding and Trailing1.
1.
9 Mining Cables1.
1.
10 Halogen-Free Cables with Improved Performance in the Case of Fire1.
2 Determination of the Cross-Sectional Area of Cables1.
2.
1 General1.
2.
2 Determination of the Cross-Sectional Area for Normal Operation1.
2.
3 Determination of the Cross-Sectional Area for Short-Circuit1.
2.
4 Determination of the Cross-Sectional Area for the Permitted Voltage Drop.
1.
2.
5 Protection Against Overcurrents1.
2.
6 Maximum Permissible Cable Lengths in Power Cable Installations with Nominal Voltages up to 1000 V2 Project Planning Data of Cables2.
1 Building Wires and Cables2.
2 Single-Core Cables for Internal Wiring, General and Special Purposes2.
3 Heat-Resistant Cables and Cords2.
4 Cables for Measuring, Controlling and Regulating (MSR)2.
5 Flexible PVC-Sheathed Cords2.
6 Flexible Rubber-Sheathed Cords and Cables2.
7 Welding Cables2.
8 Flexible Cables for Forced Guiding and Trailing2.
9 Mining Cables2.
10 Halogen-Free Cables with Improved Performance in the Case of Fire3 Explanations to the Project Planning Data of CablesPower Cables4 Selection of Cables4.
1 Summary and Application4.
1.
1 PROTODUR Cables (PVC Insulation) with Copper Conductor4.
1.
2 PROTOTHEN X Cables (XLPE Insulation) with Copper Conductor4.
1.
3 Halogen-Free Cables with Improved Performance in the Case of Fire (SIENOPYR FRNC Cables) with Copper Conductor4.
1.
4 Cables with Paper Insulation and Copper Conductor4.
1.
5 PROTODUR Cables (PVC Insulation) with Aluminium Conductor4.
1.
6 PROTOTHEN X Cables (XLPE Insulation) with Aluminium Conductor4.
1.
7 Cables with Paper Insulation and Aluminium Conductor4.
2 Determination of the Cross-Sectional Area of Cables4.
2.
1 General4.
2.
2 Determination of the Cross-Sectional Area for Normal Operation4.
2.
3 Determination of the Cross-Sectional Area for Short-Circuit4.
2.
4 Determination of the Cross-Sectional Area for the Permitted Voltage Drop4.
2.
5 Protection Against Overcurrents4.
2.
6 Determination of the Cross-Sectional Area of Ship Cables5 Project Planning Data of Power Cables5.
1 PROTODUR Cables (PVC Insulation)5.
2 PROTOTHEN X Cables (XLPE Insulation)5.
3 SIENOPYR FRNC Cables (Halogen-Free Cables with Improved Performance in the Case of Fire)5.
4 Cables with Paper Insulation with Copper Conductor5.
5 PROTODUR Cables (PVC Insulation)5.
6 PROTOTHEN X Cables (XLPE Insulation)5.
7 Cables with Paper Insulation6 Explanations to the Project Planning Data of CablesAccessories for Power Cables7 Summary of Accessories8 Project Planning Data of Accessories8.
1 Indoor Terminations8.
2 Outdoor Terminations8.
3 Spreader Boxes8.
4 Separable Elbow Connectors8.
5 Straight Joints8.
6 Branch Joints8.
7 Transition Joints9 Explanations to the Project Planning Data of Accessories